Critical Power, Data Center
Univision
San Jose, CA
- Owner: Univision Communications Inc.
- Architect: IA Interior Architects
- Engineer: ARC Engineers
- Construction: $24,800,000
- Electrical: $2,683,000
Univision is the largest Spanish television and radio broadcasting network in the United States. The network airs entertainment, news, and sports programming and is aimed at serving a Hispanic American audience.
Howell Electric was selected to provide pre-construction, electrical construction, fire alarm systems, emergency power systems, infrastructure for three large satellite dishes, and a 150’ radio broadcast tower for Univision’s 45,000sf media center in San Jose.
This facility features: 4,000sf Data Center, 2,400sf newsroom studio, 3,000sf television studio, three radio station studios, high end Class A office space, conference rooms, and break room.
The emergency electrical systems consisted of a 2000Amp 480Volt electrical service, 750kW emergency generator, 300kW UPS, and a dual feed redundant emergency power distribution system to support the data center.
Features:- 4000sf In-house Data Center
- 750kW Emergency Generator
- 300kVA UPS System
- Electrical Infrastructure for TV Studios and News Rooms
- Three Large Broadcast Satellite Dishes and a Large Radio Broadcast Tower
Complete Genomics, Inc.
San Jose, CA
- Owner: M West Propco X LLC
- Architect: DGA Architects
- Engineer: Howell Electric
- Construction: $ 20,400,000
- Electrical: $3,101,000
Complete Genomics is an established technology leader in whole human genome sequencing based in San Jose, California. Using its proprietary sequencing instruments, chemistry, and software, the company has sequenced more than 20,000 whole human genomes. The company’s mission is to improve human health by providing researchers and clinicians with the core technologies to understand, prevent, diagnose, and treat diseases and conditions.
Howell Electric was selected to provide pre-construction services, electrical engineering, electrical construction, data cabling, fire alarm systems, security systems, access controls, CCTV, and commissioning for Complete Genomics new 68,513sf corporate office and life science facility.
This facility features: In-house data center, multiple large sequencing labs wit h precision humidity controls, sample labs, wet labs, large general purpose labs, lab support, state of the art executive briefing center, open office areas, private offices, conference rooms, large break room, and all hands areas.
MEP systems consisted of new 3000Amp 480Volt electrical service, in-house data center with 1.50MW emergency generator, 500kW uninterruptible power system, extensive distribution for commercial and emergency power systems, electrical distribution to sequencing robots, IT equipment, 210-Ton chiller plant, boilers, CDA, and VAC systems.
Features:- New 3000Amp Electrical Service
- In-house Data Center with 1.5MW generator and 500kW UPS
- Data Cabling, Fire System, Security Systems, Access control, and CCTV
AT&T
Milpitas, CA
- Engineer: Alessi Engineering
AT&T is the largest communications company in the world.
Howell Electric was selected to provide electrical construction and commissioning for AT&T’s electrical service and generator upgrade at their Milpitas Data Center.
This project features: a new 4000Amp 480Volt bussed electrical service. 1MW emergency generator, 3000Amp emergency power distribution, multiple automatic transfer switches, and interfacing with the existing DC power system. Existing electrical systems were transferred to the new installation without interruption.
Features:- 4000Amp 480Volt Electrical Service Installed in an Opening Data Center
- 1MW Generator Installation
- Existing Electrical Systems Transferred to New Electrical Service without Interruption
Magma Design Automation Data Center Expansion
Santa Clara, CA
- Architect: Archespace GWSC
- Engineer: Green Engineers
Magma Design Automation develops software for Electronic Design Automation (EDA) enabling integrated circuit designers to meet critical time-to-market objectives, improve chip performance, and handle multi-million gate designs.
Howell Electric was selected to provide electrical construction, UPS systems, generator systems, and commissioning for Magma Design Automation’s request to double the size and capacity of their Santa Clara data center.
This project features: 1.5MW generator, 3000Amp 480Volt automatic transfer switch, 3000Amp 480Volt emergency distribution systems, 500kVA UPS, 500kVA transformer with redundant distribution to all server cabinets, 70-Ton air cooled chiller with four large CRAC units. All work was completed with no down time to existing data center.
Features:- 1.5MW Generator
- 500kVA UPS
- 3000Amp 480Volt Emergency Distribution System Installed with No Down Time to the Existing Data Center
IBM / Rational Software
Cupertino, CA
- Architect: Bunton Architecture
- Engineer: Howell Electric
IBM manufactures and sells computer hardware, software, and it offers infrastructure, hosting, and consulting services in areas ranging from mainframe computers to nanotechnology.
Howell Electric was selected to provide pre-construction services, design-build services, and electrical construction for two building tenant improvement.
This two building facility features: 145,000sf of Class A corporate offices, conference rooms, engineering labs, 3000sf data center, 350kW emergency generator, parallel 100kW UPS systems, and building interconnect.
Features:- Two Buildings Totaling 145,000sf
- 350kW Emergency Generator
- Parallel 100kW UPS Systems
Logitech
Fremont, CA
- Architect: ID/Architecture
- Engineer: Howell Electric
- Construction Manager: CBRE
Logitech designs and sells a broad portfolio of interface devices for computers, console games, and home entertainment system.
Howell Electric was selected to provide pre-construction services, design-build services, and electrical construction for Logitech’s 45,000 sf expansion.
This project features: 45,000 sf of engineering labs, high-end office areas and a data center expansion, 2000Amp 480Volt electrical service upgrade to an operational building, 350kW emergency generator, 225kVA UPS, and redundant emergency distribution system.
Features:- 45,000sf Expansion
- 350kW Emergency Generator
- Parallel redundant UPS systems
- New 2000Amp Electrical Service Upgrade
Additional Critical Power | Data Center Clients
Equinix
Switch & Data
Nimble Storage
FBI Data Center
IBM
Infosys
Pioneer Hi-bred
Guardant Health
Ciena
Relypsa
Intrexon
Impax Labs
Allogene
Blue Arc
Agenus
Rational
Intarcia
Ardelyx
Medimmune
Broad Base
AstraZeneca
Verinata Health
Arcus Biosciences
Vantage Data Centers